Code |
Description |
100-xxx |
Batch controller Batching Master 110 (i) / 210 (i) |
Order Code: |
Product Description: |
100-0110 |
Batching Master 110i |
|
Intrinsically safe field housing device, IP65, ATEX |
100-0120 |
Batching Master 110 |
|
Non-Ex, field housing IP65 |
100-0130 |
Batching Master 210i |
|
Intrinsically safe panel mount device, ATEX |
100-0140 |
Batching Master 210 |
|
Non-Ex, panel mount device |
100-0145 |
Backlight for the LCD |
|
This option requires an additional power supply module PSC 300i for |
|
intrinsically safe devices |
100-0150 |
Modbus interface |
|
TTY at intrinsically safe devices, RS485 at non-Ex devices |
|
This option requires an IPC 300i module for intrinsically safe devices |
100-0160 |
Terminal function |
|
This price includes the price for the option Modbus interface |
100-0165 |
Custody transfer version |
|
This price includes the price for the option Modbus interface |
100-0170 |
PID controller function |
100-0175 |
Flow correction function |
|
Calculation between mass flow, volume flow and volume flow at |
|
standard temperature |
120-0180 |
Automatic purge function “Filling and Emptying” |
|
Special software function |
|
Function keys F1-F3 |
100-0191 |
3 product ways |
100-0192 |
3 fixed pre-selections |
100-0193 |
3 fixed controller set points |
100-0200 |
Emergency stop as a key switch |
|
only for field housing devices available |
Accessories / Interface Cards: |
A-100-0210 |
Intrinsically safe power supply module |
|
PSC 300i, 1-channel |
|
DIN rail housing, 24V power supply |
A-100-0220 |
Interface and power supply module IPC 300i |
|
DIN rail housing, 24V power supply |
|
- interface barrier between intrinsically safe and RS485, non-Ex |
|
- one intrinsically safe power supply output |
|
|
200-xxx |
Exi PID controller CTR 210i |
Order Code: |
Product Description: |
200-0110 |
CTR 210i |
|
Intrinsically safe panel mount device, ATEX approval |
200-0130 |
Pt100 temperature input |
|
Price for each analogue input as Pt100 (3-wire) |
200-0150 |
Modbus interface |
|
This option requires an IPC 300i interface module |
Software Functions: |
|
200-0160 |
Cascade controller function |
220-0170 |
Automatic setpoint ramp function |
|
With 16 steps |
200-0180 |
Double loop controller software |
200-0190 |
Manual / Automatic station |
|
Special software |
200-0200 |
Setpoint station |
|
Special software |
Accessories / Interface Cards: |
A-200-0210 |
Field housing |
|
IP65 |
A-200-0220 |
Intrinsically safe power supply module |
|
PSC 300i, 1-channel |
|
DIN rail housing, 24V power supply |
A-200-0230 |
Intrinsically safe power supply module |
|
PSC 300i, 2-channel |
|
DIN rail housing, 24V power supply |
|
Channel one for the first power supply of the CTR 210i |
|
Channel two only for the second power supply of the CTR 210i |
A-200-0240 |
Interface and power supply module IPC 300i |
|
DIN rail housing, 24V power supply |
|
- interface barrier between intrinsically safe and RS485, non-Ex |
|
- one intrinsically safe power supply output |
|
|
300-xxx |
Exi Bargraph indicator BGI 210 (i) |
Order Code: |
Product Description: |
300-0110 |
BGI 210i |
|
Intrinsically safe panel mount device, ATEX approval |
300-0130 |
Pt100 temperature input |
|
Price for each analogue input as Pt-100 (3-wire) |
300-0150 |
Modbus interface |
|
This option requires an IPC 300i interface module |
Accessories / Interface Cards: |
A-300-0160 |
Field housing |
|
IP65 |
A-300-0170 |
Intrinsically safe power supply module |
|
PSC 300i, 1-channel |
|
DIN rail housing, 24V power supply |
A-300-0180 |
Intrinsically safe power supply module |
|
PSC 300i, 2-channel |
|
DIN rail housing, 24V power supply |
|
Channel one for the first power supply of the BGI 210i |
|
Channel two only for the second power supply of the BGI 210i |
A-300-0190 |
Interface and power supply module IPC 300i |
|
DIN rail housing, 24V power supply |
|
- interface barrier between intrinsically safe and RS485, non-Ex |
|
- one intrinsically safe power supply output |
|
|
400-xxx |
Exi Recorder ExTrend 200i |
Order Code: |
Product Description: |
400-0110 |
ExTrend 200i, 6-channel |
|
Intrinsically safe chart recorder in panel mount housing |
|
Power supply via IPM 300i interface module (see A-400-0150) |
|
6 x analogue inputs Pt100 or 4-20 mA, passive |
|
6 x digital inputs, active |
|
6 x digital outputs, passive |
|
Intrinsically safe interface with Modbus protocol |
400-0120 |
ExTrend 200i, 3-channel |
|
Intrinsically safe chart recorder in panel mount housing |
|
Power supply via IPM 300i interface module (see A-400-0150) |
|
3 x analogue inputs Pt100 or 4-20 mA, passive |
|
6 x digital inputs, active |
|
6 x digital outputs, passive |
|
Intrinsically safe interface with Modbus protocol |
Accessories / Interface Cards: |
A-400-0150 |
Interface and power supply module IPM 300i |
|
DIN rail housing, 24V power supply |
|
- interface barrier between intrinsically safe and RS485, non-Ex |
|
- two intrinsically safe power supply outputs |
|
|
500-xxx |
Batch controller BC 20 |
Order Code: |
Product Description: |
500-0110 |
BC 20 - DC |
|
Panel mount housing 96 x 96 x 120 mm |
|
LC-display with backlight, 2 x 16 characters, 5,6 mm height |
|
Power supply 24 VDC |
|
3 x analogue input, 4-20 mA, passive |
|
1 x pulse input, active |
|
3 x digital input, active |
|
2 x optocoupler output, passive, Imax = 50 mA |
|
2 x relay output, passive change-over contact, Imax= 3A, Umax= 250V |
|
1 x valve output signal, 4-20 mA, active, optional |
|
(see 500-0130 or 500-0140) |
|
1 x RS485 interface with Modbus protocol, optional |
|
(see 500-0150) |
500-0120 |
BC 20 - AC |
|
Panel mount housing 96 x 96 x 120 mm |
|
LC-display with backlight, 2 x 16 characters, 5,6 mm height |
|
Power supply 85-240 VAC, 47-63Hz |
|
3 x analogue input, 4-20 mA, passive |
|
1 x pulse input, active |
|
3 x digital input, active |
|
2 x optocoupler output, passive, Imax = 50 mA |
|
2 x relay output, passive change-over contact, Imax= 3A, Umax= 250V |
|
1 x valve output signal, 4-20 mA, active, optional |
|
(see 500-0130 or 500-0140) |
|
1 x RS485 interface, Modbus protocol, optional |
|
(see 500-0150) |
500-0130 |
Valve output signal 4-20 mA, active |
|
With a start-up ramp and a 5-step shut-off ramp |
500-0140 |
Valve output signal with PID flow control function |
|
PID control function for the flow rate control during the batch. |
|
Price includes 500-0130 |
500-0150 |
RS485 interface with Modbus protocol |
|
|
600-xxx |
Flow computer Pipeline Master 110 (i) / 210 (i) |
Order Code: |
Product Description: |
600-0110 |
Pipeline Master 110i |
|
Intrinsically safe field housing device, IP65, ATEX approval |
600-0120 |
Pipeline Master 110 |
|
Non-Ex, field housing IP65 |
600-0130 |
Pipeline Master 210i |
|
Intrinsically safe panel mount device, ATEX approval |
600-0140 |
Pipeline Master 210 |
|
Non-Ex, panel mount device |
600-0145 |
Back light for the LCD |
|
This option requires an additional power supply module PSC 300i for |
|
intrinsically safe devices |
600-0150 |
Modbus interface |
|
TTY at intrinsically safe devices, RS485 at non-Ex devices |
|
This option requires an IPC 300i module for intrinsically safe devices |
600-0160 |
Terminal function |
|
This price includes the price for the option Modbus interface |
600-0165 |
Custody transfer version |
|
This price includes the price for the option Modbus interface |
600-0175 |
Flow correction function |
|
Calculation between mass flow, volume flow and volume flow at |
|
standard temperature |
Accessories / Interface Cards: |
A-600-0210 |
Intrinsically safe power supply module |
|
PSC 300i, 1-channel |
|
DIN rail housing, 24V power supply |
A-600-0220 |
Interface and power supply module IPC 300i |
|
DIN rail housing, 24V power supply |
|
- interface barrier between intrinsically safe and RS485, non-Ex |
|
- one intrinsically safe power supply output |
|
|
700-xxx |
PCC 400 Printer control system |
|
with data storage function |
Order Code: |
Product Description: |
PCC 400 for the Batching Master: |
700-0110 |
PCC 400 for 1-8 Batching Masters |
|
One additional interface module EX9520R is required. |
700-0120 |
PCC 400 for 1-16 Batching Masters |
|
One additional interface module EX9520R is required. |
Optional software functions for 700-0110 and 700-0120: |
700-0130 |
Terminalfunktion for the input of max. 10 information before |
|
the batch start |
700-0131 |
Selection of 7 product ways |
|
The product ways will be switched via the Modbus relay |
|
module EX90670D-M. (Price see A-700-0320) |
700-0132 |
Automatic writing function into an external MySQL data |
|
base |
PCC 400 für Pipeline Master: |
700-0210 |
PCC 400 for 1-8 Pipeline Masters |
|
One additional interface module EX9520R is required. |
700-0210 |
PCC 400 for 1-16 Pipeline Masters |
|
One additional interface module EX9520R is required. |
Accessories / Interface Cards: |
A-700-0310 |
Interface converter EX9520R from RS232 to RS485 |
A-700-0320 |
Modbus relay module EX9067D-M |
A-700-0410 |
Printer IBS ML 3320 with CT approval incl. serial interface |